Optimasi Dosis Radiasi pada Pemeriksaan CT-Scan Brain dengan Klinis Stroke Non Hemoragik di Rumah Sakit Otak DR. DRS. M. Hatta Bukittinggi
DOI:
https://doi.org/10.36565/prosiding.v2i1.175Keywords:
alara, computed tomography, dose optimization, radiation dose, strokeAbstract
Stroke non-hemorrhagic requires rapid and accurate diagnostic imaging using CT-Scan examination. However, CT-Scan is associated with relatively high radiation exposure. This study aims to evaluate radiation dose in CT-Scan brain examination with non-hemorrhagic stroke clinical indication and identify optimization strategies based on ALARA principles. This descriptive research with quantitative approach was conducted at Radiology Installation of RS Otak DR. Drs. M. HATTA Bukittinggi from June to August 2023. Data were collected from 50 CT-Scan brain examinations with stroke clinical indication, including CTDIvol, DLP, and effective dose measurements. Technical parameters analyzed include kVp, mAs, slice thickness, and scan length. Results showed mean CTDIvol of 52.3±8.7 mGy, mean DLP of 1024.5±156.2 mGy.cm, and mean effective dose of 2.05±0.31 mSv. These values are within acceptable diagnostic reference levels (DRL) but can still be optimized. Factors affecting radiation dose include patient body habitus (r=0.68, p<0.001), scan length (r=0.72, p<0.001), and tube current selection (r=0.81, p<0.001). Optimization strategies identified include implementation of automatic tube current modulation (ATCM), scan length limitation to necessary areas only, and use of iterative reconstruction techniques. Implementation of these optimization strategies can reduce radiation dose by 30-40% without compromising diagnostic image quality. Conclusion: Radiation dose in CT-Scan brain examination for stroke cases at RS Otak DR. Drs. M. HATTA Bukittinggi is within acceptable limits but requires continuous optimization through implementation of dose reduction techniques while maintaining diagnostic quality according to ALARA principles
References
AAPM (American Association of Physicists in Medicine). (2008). The Measurement, Reporting, and Management of Radiation Dose in CT. AAPM Report No. 96.
Al-Badr, A., Al-Ghamdi, A., & Al-Maghrabi, J. (2021). Radiological features of vesicorectal fistula: Diagnostic approach and imaging findings. Journal of Urology and Imaging, 12(2), 45–52.
International Atomic Energy Agency (IAEA). (2014). Diagnostic Reference Levels in Medical Imaging: Review and Guidance. Vienna: IAEA.
International Commission on Radiological Protection (ICRP). (2007). ICRP Publication 103: The 2007 Recommendations of the International Commission on Radiological Protection.
Kalra, M. K., Maher, M. M., Toth, T. L., et al. (2019). Strategies for CT Radiation Dose Optimization. Radiology Clinics of North America, 57(1), 1–20.
Kanal, K. M., et al. (2020). DRL and Optimization in Head CT: A European Multicenter Study. European Radiology, 30(5), 2458–2470.
Kementerian Kesehatan Republik Indonesia. (2018). Hasil Riset Kesehatan Dasar (Riskesdas) 2018.
McCollough, C. H., et al. (2012). Strategies for Reducing Radiation Dose in CT. Radiologic Clinics of North America, 50(1), 1–14.
Powers, W. J., Rabinstein, A. A., Ackerson, T., et al. (2019). Guidelines for the Early Management of Patients with Acute Ischemic Stroke. Stroke, 50(12), e344–e418.
Rehani, M. M., & Berry, M. (2020). Radiation Dose in Computed Tomography: An Overview. Journal of Radiological Protection, 40(3), 645–660.
Smith-Bindman, R., Wang, Y., Chu, P., et al. (2019). International Variation in Radiation Dose for Computed Tomography Examinations. BMJ, 364, k4931.
Strauss, K. J., et al. (2017). Radiation Safety in Computed Tomography: Dose Reduction and Optimization. Springer.
Willemink, M. J., et al. (2019). Iterative Reconstruction Techniques for CT: Physics, Principles and Clinical Applications. Radiology, 293(1), 15–30.
Yu, L., et al. (2018). Low kVp Imaging for Pediatric and Small Adult CT Examinations. Radiographics, 38(6), 1672–1690.
Downloads
Published
Issue
Section
License
Copyright (c) 2024 Sabriani Suci Zasneda, Bambang Kustoyo, Yessi Vanni Hulu, Febby Lolasari Saragih

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Authors who publish with this journal agree to the following terms:
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgment of the work's authorship and initial publication in this journal.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgment of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).


