Pengaruh Tegangan Tabung (Kv) pada Pemeriksaan Thorax terhadap Kualitas Citra Radiografi di RS Efarina Pangkalan Kerinci
DOI:
https://doi.org/10.36565/prosiding.v1i1.101Keywords:
image quality, image-j, tube voltage, thorax examination, x-rayAbstract
X-ray tube voltage is one of the exposure factors that significantly influence the quality of radiographic images. The use of standard versus high voltage can impact the contrast and sharpness of thoracic radiographic images. This study aims to determine the effect of variations in tube voltage in thoracic examinations on radiographic image quality. This experimental study was conducted at Efarina Hospital, Pangkalan Kerinci, using a Toshiba X-ray machine model DRX-1824B. Irradiation was carried out using standard voltage (50-70 kV) and high voltage (90-110 kV) with a distance of 100 cm and a time of 10 mAs. Image quality was analyzed using Image-J software with a histogram feature. Standard voltage (50 kV) produced good radiographic image quality with clear histogram readings, showing the black background position from 16 to 36 and the object position from 37 to 79, allowing clear differentiation between the object edge and the background. High voltage (90 kV) results in reduced contrast, with a dominant grayscale gradient from positions 10 to 132, making objects and background indistinguishable. Standard tube voltage provides better radiographic image quality than high voltage for thoraxt examinations.
References
BATAN. (2005). Desain Penahan Ruang Sinar-X. Pusdiklat BATAN.
Bushong, C. S. (2001). Radiology Science for Technology: Physics, Biology, and Protection (7th ed.). Mosby Company.
Carrol, Q. B. (1985). Principle of Radiographic Exposure Processing and Quality Control (3rd ed.). Thomas Publisher.
Hernawati, S. (2012). Gelombang. Alauddin University Press.
Kurniawan, A., Santoso, B., & Wijaya, D. (2021). Optimasi Parameter Eksposur Radiografi Thorax untuk Meningkatkan Kualitas Citra. Jurnal Radiologi Indonesia, 15(2), 112-120.
Lee, S. C. (2007). Nuclear Instruments and Methods in Physics Research. ROC.
Nurkhamid, M., & Sutejo. (2012). Metode Kecerahan Citra Kontras dan Penajaman Citra untuk Peningkatan Mutu Citra. Universitas Indonesia.
Patel, P. R. (2005). Lecture Notes: Radiologi. Erlangga.
Pratama, R., & Kusuma, H. (2020). Analisis Histogram sebagai Metode Objektif Evaluasi Kualitas Citra Radiografi. Indonesian Journal of Radiology, 12(1), 45-52.
Rasad, S. (1999). Radiologi Diagnostik Pencitraan Diagnosis (Edisi Pertama). FKUI.
Rasad, S. (2005). Radiologi Diagnostik (Edisi Kedua). FKUI.
Santoso, D., & Wibowo, T. (2019). Perbandingan Kualitas Citra Radiografi dengan Variasi kVp pada Pemeriksaan Thorax. Jurnal Imaging Diagnostik, 6(2), 78-85.
Sutikno, K., Firdausy, & Prasetyo, E. (2007). Perangkat Lunak Perbaikan Kualitas Citra Digital Model RGB dan HIS dengan Operasi Peningkatan Kontras. SNATI.
White, S., & Pharoah, M. (2014). Oral Radiology Principle and Interpretation (7th ed.). Elsevier Mosby.
Wijaya, K., & Suryani, L. (2022). Pengaruh Faktor Eksposur terhadap Kualitas Citra Radiografi Digital. Jurnal Teknologi Radiologi, 9(1), 23-30.
Downloads
Published
Issue
Section
License
Copyright (c) 2023 Bambang Kustoyo, Christine Dear Hara Saragih

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Authors who publish with this journal agree to the following terms:
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgment of the work's authorship and initial publication in this journal.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgment of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).